Export (0) Print
Expand All
This topic has not yet been rated - Rate this topic

Set-SPPowerPointConversionServiceApplication

SharePoint 2013

Published: August 21, 2012

Applies to:  SharePoint Server 2013 Standard | SharePoint Server 2013 Enterprise 

Configures settings for a PowerPoint Conversion Service application.

Set-SPPowerPointConversionServiceApplication [-Identity] <SPPowerPointConversionServiceApplicationPipeBind> [-AssignmentCollection <SPAssignmentCollection>] [-CacheExpirationPeriodInSeconds <UInt32>] [-MaximumConversionsPerWorker <UInt32>] [-WorkerKeepAliveTimeoutInSeconds <UInt32>] [-WorkerProcessCount <UInt32>] [-WorkerTimeoutInSeconds <UInt32>]

Parameters

Parameter Required Type Description

Identity

Required

Microsoft.Office.Server.PowerPoint.PowerShell.SPPowerPointConversionServiceApplicationPipeBind

Specifies the unique name of this PowerPoint Conversion Service application.

AssignmentCollection

Optional

Microsoft.SharePoint.PowerShell.SPAssignmentCollection

Manages objects for the purpose of proper disposal. Use of objects, such as SPWeb or SPSite, can use large amounts of memory and use of these objects in Windows PowerShell scripts requires proper memory management. Using the SPAssignment object, you can assign objects to a variable and dispose of the objects after they are needed to free up memory. When SPWeb, SPSite, or SPSiteAdministration objects are used, the objects are automatically disposed of if an assignment collection or the Global parameter is not used.

noteNote:

When the Global parameter is used, all objects are contained in the global store. If objects are not immediately used, or disposed of by using the Stop-SPAssignment command, an out-of-memory scenario can occur.

CacheExpirationPeriodInSeconds

Optional

System.UInt32

Specifies the maximum time, in seconds, that items remain in the back-end server cache. The default value is 600 seconds (10 minutes).

MaximumConversionsPerWorker

Optional

System.UInt32

Specifies the maximum number of presentations that a conversion worker process can convert before recycling. The default value is 5.

WorkerKeepAliveTimeoutInSeconds

Optional

System.UInt32

Specifies the maximum time, in seconds, that a conversion worker process can be unresponsive before being terminated. The default value is 120 seconds.

WorkerProcessCount

Optional

System.UInt32

Specifies the number of active instances of the conversion worker process on each back-end. This value must be less than the Windows Communication Foundation (WCF) connection limit for this computer. The default value is 3.

WorkerTimeoutInSeconds

Optional

System.UInt32

Specifies the maximum time, in seconds, that a conversion worker process is given for any single conversion. The default is 300 seconds (5 minutes).

Detailed Description

Use the Set-SPPowerPointConversionServiceApplication cmdlet to set properties and settings for an instance of a PowerPoint Conversion Service application that is in a farm.

Input Types

Return Types

-----------EXAMPLE 1-------

Set-SPPowerPointConversionServiceApplication -Identity "MyWorkgroupPPTApp" -CacheExpirationPeriodInSeconds 1200

This example establishes new operational defaults for the conversion cache expiration.

-----------EXAMPLE 2-------

Set-SPPowerPointConversionServiceApplication -Identity "MyWorkgroupPPTApp" -DisableBinaryScan:$false

This example disables binary scanning of documents.

Change History

Date Description

August 21, 2012

Initial publication

Did you find this helpful?
(1500 characters remaining)
Thank you for your feedback
Show:
© 2014 Microsoft. All rights reserved.