LoadMemoryLimit Property
LoadMemoryLimit Property
Gets and sets the number of megabytes of computer memory that is allocated to Telephony Application Services (TAS).
obj.LoadMemoryLimit = integer
Part |
Description |
---|---|
obj |
An instance of the TAS class. |
integer |
An unsigned integer specifying the number of megabytes of the computer's physical memory that are allocated to TAS. |
Qualifiers
Qualifier |
Value |
Description |
---|---|---|
Registry |
False |
If True, this property value is read from the Registry. |
Restart |
False |
If False, changes to this property take effect without requiring the service to restart. |
DefaultValue |
500 |
Default value for this property. |
MinValue |
0 |
Minimum value for this property. |
MaxValue |
4000 |
Maximum value for this property. |
Remarks
This property is exposed in the Microsoft Speech Server Management Console snap-in.
When the memory use exceeds this threshold, SALT interpreter creation is throttled, and unused interpreters are retired until memory use returns to acceptable working boundaries.
Windows Management Instrumentation (WMI) Script Example
myComputer = "localhost" ' Use a Locator object to connect to WMI. Set locator = CreateObject("WbemScripting.SWbemLocator") Set namespace = locator.ConnectServer(myComputer, "root/MSS") ' Get the TAS instance. Set tel = namespace.Get("TAS=@") ' Display the current value. WScript.Echo tel.LoadMemoryLimit ' Set the property value. tel.LoadMemoryLimit = 1000 ' Update the class instance in WMI. tel.Put_