PERF_100NSEC_MULTI_TIMER
Applies To: Windows Server 2003, Windows Server 2003 R2, Windows Server 2003 with SP1, Windows Server 2003 with SP2
Description |
This counter type shows the active time of one or more components as a percentage of the total time of the sample interval. It measures time in 100 nanosecond units. This counter type is a multitimer. Multitimers are designed to monitor more than one instance of a component, such as a processor or disk. |
Generic type |
Percentage. |
Formula |
((N1 - N0) / (D1 - D0)) x 100 / B, where the denominator (D) represents the total elapsed time of the sample interval, the numerator (N) represents the portions of the sample interval during which the monitored components were active, and the variable B represents the base count for the monitored components. |
Average |
((Nx - N0) / (Dx - D0) ) x 100 / B |
Example |