Event Message:

The redirector failed to allocate a multiplex table entry. This indicates that the MAXCMDS parameter to the redirector is insufficient for the users needs.

Source

Event Log

Event ID

Event Type

Rdr

System

3021

Error

Explanation:

The MAXCMDS registry entry specifies the maximum number of work buffers that the redirector reserves for performance reasons. The default is 15. If your application performs more than 15 simultaneous operations, consider increasing the value of this entry. Because this entry controls the number of execution threads that can be simultaneously outstanding at any time, your network performance will not always be improved by increasing the value of this entry. Each additional execution thread takes about 1K of nonpaged pool if you load up the network. Resources will not be consumed, however, unless the user actually makes use of them.

User Action:

Ask the person with administrative rights on your computer to increase the value of the MAXCMDS entry in the \LanmanWorkstation subkey of the registry to improve your network throughput.