Event Message:

WINS could not start because the existent database must be converted to the Windows 2000 format. If this is the first invocation of WINS after an upgrade From NT 3.51, you need to run the convert utility (upg351db.exe in the %%SystemRoot%%\\system32 directory) on the WINS database to convert it to the new database format. Once you have done that, you should restart WINS.

Source

Event Log

Event ID

Event Type

Wins

System

4319

Error

Explanation:

If this is the first invocation of WINS after an upgrade from Windows NT 3.51, you need to run the conversion utility (upg351db.exe in the winnt\system32 folder) on the WINS database to convert it to the new, improved database format. Once the database has been converted, restart WINS.

User Action:

To upgrade: 1) Run upg351db.exe from the winnt\system32 folder. 2) After the upgrade is complete, restart WINS.