Remove-SCOMTierConnector
Updated: September 10, 2012
Applies To: System Center 2012 - Operations Manager, System Center 2012 SP1 - Operations Manager
Remove-SCOMTierConnector
Syntax
Parameter Set: Default Remove-SCOMTierConnector -Connector <MonitoringConnector> -Tier <TieredManagementGroup> [-ComputerName <String[]> ] [-Credential <PSCredential> ] [-SCSession <Connection[]> ] [-Confirm] [-WhatIf] [ <CommonParameters>]
Detailed Description
The Remove-SCOMTierConnector cmdlet disassociates a connector from a tiered management group. Removing a connector from a tier stops that tier from transmitting monitoring information to that connector.
Parameters
-ComputerName<String[]>
Specifies a computer to establish a connection with. The computer must be running the System Center Data Access service. The default is the computer for the current management group connection.
Valid formats include a NetBIOS name, an IP address, or a fully qualified domain name. To specify the local computer, type the computer name, "localhost", or a dot (.).
|
Aliases |
none |
|
Required? |
false |
|
Position? |
named |
|
Default Value |
none |
|
Accept Pipeline Input? |
false |
|
Accept Wildcard Characters? |
false |
-Connector<MonitoringConnector>
Specifies the connector to remove.
|
Aliases |
none |
|
Required? |
true |
|
Position? |
named |
|
Default Value |
none |
|
Accept Pipeline Input? |
true (ByValue) |
|
Accept Wildcard Characters? |
false |
-Credential<PSCredential>
Specifies a user account under which the management group connection will run. It must have access to the server that is specified in the ComputerName parameter if specified. The default is the current user.
Enter a PSCredential object, such as one that is returned by the Get-Credential cmdlet.
|
Aliases |
none |
|
Required? |
false |
|
Position? |
named |
|
Default Value |
none |
|
Accept Pipeline Input? |
false |
|
Accept Wildcard Characters? |
false |
-SCSession<Connection[]>
Specifies a connection to a management server. The default is the current management group connection.
Enter a Management group connection object, such as one returned by the Get-SCManagementGroupConnection cmdlet.
|
Aliases |
none |
|
Required? |
false |
|
Position? |
named |
|
Default Value |
none |
|
Accept Pipeline Input? |
false |
|
Accept Wildcard Characters? |
false |
-Tier<TieredManagementGroup>
Specifies the tiered management group from which to remove the connector.
|
Aliases |
none |
|
Required? |
true |
|
Position? |
named |
|
Default Value |
none |
|
Accept Pipeline Input? |
true (ByValue) |
|
Accept Wildcard Characters? |
false |
-Confirm
Prompts you for confirmation before executing the command.
|
Required? |
false |
|
Position? |
named |
|
Default Value |
false |
|
Accept Pipeline Input? |
false |
|
Accept Wildcard Characters? |
false |
-WhatIf
Describes what would happen if you executed the command without actually executing the command.
|
Required? |
false |
|
Position? |
named |
|
Default Value |
false |
|
Accept Pipeline Input? |
false |
|
Accept Wildcard Characters? |
false |
<CommonParameters>
This cmdlet supports the common parameters: -Verbose, -Debug, -ErrorAction, -ErrorVariable, -OutBuffer, and -OutVariable. For more information, see about_CommonParameters.
Examples
-------------------------- EXAMPLE 1 --------------------------
This example clears all connectors from the first defined tiered management group.
PS C:\>$tier = Get-SCOMTieredManagementGroup | Select-Object -First 1PS C:\>Get-SCOMTierConnector -Tier $tier | Remove-SCOMTierConnector -Tier $tier