Export (0) Print
Expand All
This topic has not yet been rated - Rate this topic

Connect Pilot Pool to Legacy Edge Servers

Lync Server 2013
 

Topic Last Modified: 2012-09-29

After deploying Lync Server 2013, you need to configure a federation route for your site. In order to use the federated route that is being used by Lync Server 2010, Lync Server 2013 must be configured to use this route.

To enable the Lync Server 2013 site to use the Director and Edge Server of the Lync Server 2010 deployment, use Topology Builder to associate the legacy Edge pool.

  1. Open Topology Builder.
  2. Select your site, which is directly below the Lync Server node.
  3. On the Actions menu, click Edit Properties.
  4. In the left pane, select Federation route.
  5. Under Site federation route assignment, select Enable SIP federation, and then select the Lync Server 2010 Director, or the Lync Server 2010 Edge Server if no Director is listed.
    5f1d04c3-c724-426d-b27d-3fe89c6c5cfb
  6. Click OK to close the Edit Properties page.
  7. In Topology Builder, under the Lync Server 2013 node, navigate to the Standard Edition server or Enterprise Edition Front End pools, right-click the pool, and then click Edit Properties.
  8. Under Associations, select the check box next to Associate Edge pool (for media components).
  9. From the list, select the legacy Edge Server.
    feae8156-540e-4804-bb0a-2b5736ec2900
  10. Click OK to close the Edit Properties page.
  11. In Topology Builder, select the top-most node, Lync Server.
  12. From the Action menu, click Publish Topology, and then click Next.
  13. When the Publishing wizard completes, click Finish.
 
Did you find this helpful?