MSExchange ActiveSync 1009

 

Letztes Änderungsdatum des Themas: 2011-03-19

Dieser Artikel bietet eine Erläuterung und mögliche Lösungen für ein bestimmtes Exchange-Ereignis. Wenn Sie hier das Gesuchte nicht finden können, durchsuchen Sie die Exchange 2010-Hilfe.

Details

Product Name

Exchange

Product Version

14.0

Event ID

1009

Category

Configuration

Symbolic Name

InvalidHbiLimits

Message Text

Direct Push has detected that the configuration value for the minimum heartbeat interval is set to a value higher than the maximum heartbeat interval. Therefore, the default minimum heartbeat interval of "%1" seconds and the default maximum heartbeat interval of "%2" seconds will be used until the next time that the computer is restarted. To avoid seeing this message in the future, use Internet Information Services (IIS) Manager to correct these values. Reset the values to the default, or use other acceptable values.

Explanation

This Warning event indicates that Exchange Direct Push has detected that the configuration value for the minimum heartbeat interval is set to a value higher than the maximum heartbeat interval. This can only be caused if these settings were manually changed. This configuration is not valid. Microsoft Exchange ActiveSync reverted to the default values for minimum heartbeat interval and maximum heartbeat interval. The default minimum heartbeat interval is 60 seconds (1 minute). The default maximum heartbeat interval is 3,540 seconds (59 minutes). Exchange ActiveSync will use the default settings until the next time that the server that is running Microsoft Exchange is restarted.

Warnung

We recommend that you only change these values if that has been recommended by Microsoft Product Support Services.

User Action

To resolve this warning, manually change the settings to the default settings or other acceptable values:

  1. Start Internet Information Services (IIS) Manager.
  2. In the console tree, click Web Sites, and then click Default Web Site.
  3. Right-click Microsoft-Server-ActiveSync, and then click Properties.
  4. On the ASP.NET tab, click Edit Configuration.
  5. On the General tab, under Application settings, do one of the following:
    • Configure the MinHeartbeatInterval and MaxHeartbeatInterval settings to match the default values.
    • Configure values that are not default. When you use values that are not default, you must configure the MinHeartbeatInterval to a value lower than the MaxHeartbeatInterval. You must also configure values in the acceptable range. The acceptable range of values for the MinHeartbeatInterval is 1 to 3,540. The acceptable range of values for the MaxHeartbeatInterval is 2 to 3,540.

For More Information

Wenn dies nicht bereits der Fall ist, sollten Sie die Exchange-Tools ausführen, die für die Analyse und Problembehandlung der Exchange-Umgebung erstellt wurden. Mit diesen Tools kann sichergestellt werden, dass Ihre Konfiguration die bewährten Methoden von Microsoft einhält. Sie tragen zudem zur Identifikation und zur Lösung von Leistungsproblemen bei, und können die Nachrichtenübermittlung verbessern. Sie können diese Tools über den Knoten Toolbox in der Exchange-Verwaltungskonsole ausführen. Weitere Informationen zu diesen Tools finden Sie unter Verwalten von Tools in der Toolbox.