MSExchangeTransport 1009
Letztes Änderungsdatum des Themas: 2011-03-19
Dieser Artikel bietet eine Erläuterung und mögliche Lösungen für ein bestimmtes Exchange-Ereignis. Wenn Sie hier das Gesuchte nicht finden können, durchsuchen Sie die Exchange 2010-Hilfe.
Product Name |
Exchange |
Product Version |
14.0 |
Event ID |
1009 |
Event Source |
MSExchangeTransport |
Category |
SmtpReceive |
Symbolic Name |
SmtpReceiveMaxConnectionReached |
Message Text |
Receive connector %1 rejected an incoming connection. The maximum number of connections (%2) for this connector has been reached. |
This Warning event indicates that a Receive connector has reached the maximum permitted number of simultaneous incoming connections. This value is specified by the MaxInboundConnection parameter on the Receive connector. The default value is 5000.
To resolve this error, increase the value of the MaxInboundConnection parameter on the Receive connector by using the Set-ReceiveConnector cmdlet in the Exchange Management Shell. The valid input range for this parameter is 1 to 2147483647. To disable the inbound connection limit on a Receive connector, enter a value of unlimited.
For more information, see Set-ReceiveConnector.
Wenn dies nicht bereits der Fall ist, sollten Sie die Exchange-Tools ausführen, die für die Analyse und Problembehandlung der Exchange-Umgebung erstellt wurden. Mit diesen Tools kann sichergestellt werden, dass Ihre Konfiguration die bewährten Methoden von Microsoft einhält. Sie tragen zudem zur Identifikation und zur Lösung von Leistungsproblemen bei, und können die Nachrichtenübermittlung verbessern. Sie können diese Tools über den Knoten Toolbox in der Exchange-Verwaltungskonsole ausführen. Weitere Informationen zu diesen Tools finden Sie unter Verwalten von Tools in der Toolbox.