TechNet
Export (0) Print
Expand All
Collapse the table of content
Expand the table of content
Expand Minimize

Set-RpcClientAccess

 

Applies to: Exchange Server 2016

This cmdlet is available only in on-premises Exchange Server 2016.

Use the Set-RpcClientAccess cmdlet to modify the settings of the Microsoft Exchange RPC Client Access service on Exchange servers that have the Client Access server role installed. These settings affect Outlook clients that connect by using Outlook Anywhere (RPC over HTTP).

Set-RpcClientAccess -Server <ServerIdParameter> [-BlockedClientVersions <String>] [-Confirm [<SwitchParameter>]] [-DomainController <Fqdn>] [-EncryptionRequired <$true | $false>] [-MaximumConnections <Int32>] [-Name <String>] [-WhatIf [<SwitchParameter>]]

This example prevents Outlook Anywhere connections by Outlook 2010 clients on the server named MBX01.

Set-RpcClientAccess -Server MBX01 -BlockedClientVersions 14.0.0-14.32767.65535

This example prevents Outlook Anywhere connections by Outlook 2013 clients that don't have KB3054940 installed (version 15.0.4737.1000) on the server named MBX01.

importantImportant:
You can determine specific client software versions by parsing the RPC Client Access log files located at %ExchangeInstallPath%Logging\RPC Client Access.
Set-RpcClientAccess -Server MBX01 -BlockedClientVersions 15.0.0-15.4737.999

Outlook 2007 isn't supported in Exchange 2016, so you shouldn't see Outlook connections at or below version 12.Y.Z. However, you should monitor the RPC Client Access log to see the client versions that are connecting to your Exchange servers before you block any client versions.

To block Outlook versions for specific mailboxes, use the Set-CASMailbox cmdlet.

You need to be assigned permissions before you can run this cmdlet. Although all parameters for this cmdlet are listed in this topic, you may not have access to some parameters if they're not included in the permissions assigned to you. To see what permissions you need, see the "RPC Client Access settings" entry in the Clients and mobile devices permissions topic.

 

Parameter Required Type Description

Server

Required

Microsoft.Exchange.Configuration.Tasks.ServerIdParameter

The Server parameter specifies the Exchange server that you want to modify.

You can use any value that uniquely identifies the server. For example:

  • Name

    Example: Exchange01

  • Distinguished name (DN)

    Example: CN=Exchange01,CN=Servers,CN=Exchange Administrative Group (FYDIBOHF23SPDLT),CN=Administrative Groups,CN=First Organization,CN=Microsoft Exchange,CN=Services,CN=Configuration,DC=contoso,DC=com

  • Exchange Legacy DN

    Example: /o=First Organization/ou=Exchange Administrative Group (FYDIBOHF23SPDLT)/cn=Configuration/cn=Servers/cn=Exchange01

  • GUID

    Example: bc014a0d-1509-4ecc-b569-f077eec54942

BlockedClientVersions

Optional

System.String

The BlockedClientVersions parameter specifies the RPC client versions that aren't allowed to connect to the specified Exchange server. For example, the Microsoft Exchange RPC Client Access service rejects an Outlook Anywhere connection if the version of Outlook is the specified value, or is in the specified range.

Valid version values are in the format X.Y.Z. RPC client versions are typically reported in format X.0.Y.Z format, but for this parameter, you need to specify the value as X.Y.Z.

  • X is the major version number. For example, Outlook 2016 is 16, Outlook 2013 is 15, and Outlook 2010 is 14.

  • Y is the minor revision number, and must be less than or equal to 32767.

  • Z is the build number, and must be less than or equal to 65535.

You can specify ranges. For example, -13.32767.65535, 14.0.0-14.32767.65535, or 15.0.0-.

You can specify multiple individual values or range values separated by semicolons (;).

CautionCaution:
Be careful when you restrict client access, because Exchange server components might also use RPC to log on. Some components may report their client version as a text string, while others may report the Exchange build number. Monitor the RPC Client Access log to see the client versions that are connecting to your Exchange server before you block any client versions.

Confirm

Optional

System.Management.Automation.SwitchParameter

The Confirm switch specifies whether to show or hide the confirmation prompt. How this switch affects the cmdlet depends on if the cmdlet requires confirmation before proceeding.

  • Destructive cmdlets (for example, Remove-* cmdlets) have a built-in pause that forces you to acknowledge the command before proceeding. For these cmdlets, you can skip the confirmation prompt by using this exact syntax: -Confirm:$false.

  • Most other cmdlets (for example, New-* and Set-* cmdlets) don't have a built-in pause. For these cmdlets, specifying the Confirm switch without a value introduces a pause that forces you acknowledge the command before proceeding.

DomainController

Optional

Microsoft.Exchange.Data.Fqdn

The DomainController parameter specifies the domain controller that's used by this cmdlet to read data from or write data to Active Directory. You identify the domain controller by its fully qualified domain name (FQDN). For example, dc01.contoso.com.

EncryptionRequired

Optional

System.Boolean

The EncryptionRequired parameter specifies whether encryption is required for RPC client connections. Valid values are:

  • $true   Unencrypted RPC client connections are rejected. This is the default value.

  • $false   Unencrypted RPC client connections are allowed.

MaximumConnections

Optional

System.Int32

The MaximumConnections parameter specifies the maximum number of concurrent client connections that are allowed by the Microsoft Exchange RPC Client Access service. The default value is 65536.

noteNote:
Although you can configure a non-default value for this parameter, changes to this setting aren't enforced.

Name

Optional

System.String

The Name parameter specifies the name of the configuration object in Active Directory. By default, this parameter is set to RpcClientAccess.

WhatIf

Optional

System.Management.Automation.SwitchParameter

The WhatIf switch simulates the actions of the command. You can use this switch to view the changes that would occur without actually applying those changes. You don't need to specify a value with this switch.