Set-SCOMAlertResolutionSetting

Set-SCOMAlertResolutionSetting

Changes the alert automatic resolution settings for the management group.

Syntax

Parameter Set: Empty
Set-SCOMAlertResolutionSetting [-AlertAutoResolveDays <Int32> ] [-ComputerName <String[]> ] [-Credential <PSCredential> ] [-HealthyAlertAutoResolveDays <Int32> ] [-PassThru] [-SCSession <Connection[]> ] [-Confirm] [-WhatIf] [ <CommonParameters>]

Detailed Description

The Set-SCOMAlertResolutionSetting cmdlet changes the alert automatic resolution settings for the management group. You can configure monitors that create alerts to automatically resolve the alert when the monitor returns to a healthy state. This means that any unresolved alert for the monitor represents a problem that still exists.

Parameters

-AlertAutoResolveDays<Int32>

Specifies the number of days until Operations Manager automatically resolves active alerts that have a monitoring state of New (0).

Aliases

none

Required?

false

Position?

named

Default Value

none

Accept Pipeline Input?

true (ByPropertyName)

Accept Wildcard Characters?

false

-ComputerName<String[]>

Specifies an array of names of computers. You can use NetBIOS names, IP addresses, or fully qualified domain names (FQDNs). To specify the local computer, type the computer name, localhost, or a dot (.).

The System Center Data Access service must be running on the computer. If you do not specify a computer, the cmdlet uses the computer for the current management group connection.

Aliases

none

Required?

false

Position?

named

Default Value

none

Accept Pipeline Input?

true (ByValue)

Accept Wildcard Characters?

false

-Credential<PSCredential>

Specifies a PSCredential object for the management group connection. To obtain a PSCredential object, use the Get-Credential cmdlet. For more information, type Get-Help Get-Credential.

If you specify a computer in the ComputerName parameter, use an account that has access to that computer. The default is the current user.

Aliases

none

Required?

false

Position?

named

Default Value

none

Accept Pipeline Input?

true (ByValue)

Accept Wildcard Characters?

false

-HealthyAlertAutoResolveDays<Int32>

Specifies the number of days after the alert source for active alerts is healthy that Operations Manager automatically resolves the alerts.

Aliases

none

Required?

false

Position?

named

Default Value

none

Accept Pipeline Input?

true (ByPropertyName)

Accept Wildcard Characters?

false

-PassThru

Indicates that the cmdlet creates or modifies an object that a command can use in the pipeline. By default, this cmdlet does not generate any output.

Aliases

none

Required?

false

Position?

named

Default Value

none

Accept Pipeline Input?

true (ByPropertyName)

Accept Wildcard Characters?

false

-SCSession<Connection[]>

Specifies an array of Connection objects. To obtain a Connection object, use the Get-SCOMManagementGroupConnection cmdlet.

A connection object represents a connection to a management server. The default is the current management group connection.

Aliases

none

Required?

false

Position?

named

Default Value

none

Accept Pipeline Input?

true (ByValue)

Accept Wildcard Characters?

false

-Confirm

Prompts you for confirmation before running the cmdlet.

Required?

false

Position?

named

Default Value

false

Accept Pipeline Input?

false

Accept Wildcard Characters?

false

-WhatIf

Shows what would happen if the cmdlet runs. The cmdlet is not run.

Required?

false

Position?

named

Default Value

false

Accept Pipeline Input?

false

Accept Wildcard Characters?

false

<CommonParameters>

This cmdlet supports the common parameters: -Verbose, -Debug, -ErrorAction, -ErrorVariable, -OutBuffer, and -OutVariable. For more information, see    about_CommonParameters (https://go.microsoft.com/fwlink/p/?LinkID=113216).

Inputs

The input type is the type of the objects that you can pipe to the cmdlet.

Outputs

The output type is the type of the objects that the cmdlet emits.

Examples

Example 1: Change the automatic resolution setting for alerts

This command changes the alert resolution setting to automatically resolve active alerts in 10 days, and to automatically resolve active alerts after their alert source is healthy for 5 days.

PS C:\> Set-SCOMAlertResolutionSetting -AlertAutoResolveDays 10 -HealthyAlertAutoResolveDays 5

Get-SCOMAlertResolutionSetting