MSSQLSERVER_7988

Applies to: SQL Server

Details

Attribute Value
Product Name SQL Server
Event ID 7988
Event Source MSSQLSERVER
Component SQLEngine
Symbolic Name DBCC2_PRE_CHECKS_CHAIN_LOOP_DETECTED
Message Text System table pre-checks: Object ID O_ID. Loop in data chain detected at P_ID. Check statement terminated because of an irreparable error.

Explanation

The first phase of a DBCC CHECKDB is to do primitive checks on the data pages of critical system tables. If any errors are found, they cannot be repaired; therefore, DBCC CHECKDB terminates immediately. A page linkage loop has been detected on page P_ID. A page linkage loop occurs when the next page pointers from a page eventually return to the page.

User Action

Look for Hardware Failure

Run hardware diagnostics and correct any problems. Also examine the Microsoft Windows system and application logs and the SQL Server error log to see whether the error occurred as the result of hardware failure. Fix any hardware-related problems that are contained in the logs.

If you have persistent data corruption problems, try to swap out different hardware components to isolate the problem. Check to make sure that the system does not have write-caching enabled on the disk controller. If you suspect write-caching to be the problem, contact your hardware vendor.

Finally, you might find it useful to switch to a new hardware system. This switch may include reformatting the disk drives and reinstalling the operating system.

Restore from Backup

If the problem is not hardware related and a known clean backup is available, restore the database from the backup.

Run DBCC CHECKDB

Not applicable. This error cannot be repaired automatically. If you cannot restore the database from a backup, contact Microsoft Service and Support (CSS).