New-EtwTraceSession

Mis à jour: novembre 2015

S'applique à: Windows 10, Windows Server Technical Preview

New-EtwTraceSession

Creates an ETW trace session.

Syntaxe

Parameter Set: cim:CreateInstance0
New-EtwTraceSession [-Name] <String> [-BufferSize <UInt32> ] [-CimSession <CimSession[]> ] [-ClockType <ClockType> {Performance | System | Cycle} ] [-FlushTimer <UInt32> ] [-LocalFilePath <String> ] [-LogFileMode <UInt32> ] [-MaximumBuffers <UInt32> ] [-MaximumFileSize <UInt32> ] [-MinimumBuffers <UInt32> ] [-ThrottleLimit <Int32> ] [-Confirm] [-WhatIf] [ <CommonParameters>] [ <WorkflowParameters>]

Description détaillée

The New-EtwTraceSession cmdlet creates an Event Trace for Windows (ETW) trace session.

Paramètres

-BufferSize<UInt32>

Specifies the size, in kilobytes, of buffers. We recommend less than 1000 kilobytes. If you do not specify a value for this parameter, ETW uses the size of physical memory to calculate a default value.

Alias

none

Requis ?

false

Position ?

named

Valeur par défaut

none

Accepter l'entrée de pipeline ?

false

Accepter les caractères génériques ?

false

-CimSession<CimSession[]>

Exécute l'applet de commande dans une session distante ou sur un ordinateur distant. Entrez un nom d'ordinateur ou un objet de session, tels que le résultat d'une applet de commande New-CimSession ou Get-CimSession. La valeur par défaut est la session en cours sur l'ordinateur local.

Alias

Session

Requis ?

false

Position ?

named

Valeur par défaut

none

Accepter l'entrée de pipeline ?

false

Accepter les caractères génériques ?

false

-ClockType<ClockType>

Specifies the timer to use for the time stamp for events. Valid values are:

-- 1: Performance. Performance counter value (high resolution)
-- 2: System. System timer
-- 3: Cycle. CPU cycle counter

The default value is Performance on computers that run Windows Vista and subsequent versions of the Windows operating system. The default value is System for previous versions of the Windows operating system.

Alias

none

Requis ?

false

Position ?

named

Valeur par défaut

none

Accepter l'entrée de pipeline ?

false

Accepter les caractères génériques ?

false

-FlushTimer<UInt32>

Specifies the interval, in seconds, at which to flush trace buffers. The minimum value is one second. This forced flush is in addition to the automatic flush that occurs when a buffer is full and when the trace session stops.

For a real-time logger, the default value of zero means that the flush time is one second. You can configure a real-time logger by specifying a value of EVENT_TRACE_REAL_TIME_MODE for the LogFileMode parameter.

The default value is zero. By default, buffers are flushed only when they are full.

Alias

none

Requis ?

false

Position ?

named

Valeur par défaut

none

Accepter l'entrée de pipeline ?

false

Accepter les caractères génériques ?

false

-LocalFilePath<String>

Specifies the full path for an ETW log file.

Alias

none

Requis ?

false

Position ?

named

Valeur par défaut

none

Accepter l'entrée de pipeline ?

false

Accepter les caractères génériques ?

false

-LogFileMode<UInt32>

Specifies one or more log modes. For valid values, see Logging Mode Constants.

Specify more than one log mode, add the values of the modes. For instance, to include both EVENT_TRACE_FILE_MODE_CIRCULAR, which has a value of 0x00000002, and EVENT_TRACE_NO_PER_PROCESSOR_BUFFERING, which has a value of 0x10000000, add 0x10000000 and 0x00000002 to obtain 0x1000002.

Alias

none

Requis ?

false

Position ?

named

Valeur par défaut

none

Accepter l'entrée de pipeline ?

false

Accepter les caractères génériques ?

false

-MaximumBuffers<UInt32>

Specifies the maximum number of buffers to allocate to the ETW session. We recommend a value of the MinimumBuffers parameter plus twenty. The value must be greater than or equal to MinimumBuffers. If you do not specify a value for the current parameter, ETW uses the buffer size and the size of physical memory to calculate a default value.

Alias

none

Requis ?

false

Position ?

named

Valeur par défaut

none

Accepter l'entrée de pipeline ?

false

Accepter les caractères génériques ?

false

-MaximumFileSize<UInt32>

Specifies the maximum size, in megabytes, of a log file. The session is closed when the maximum size is reached, unless the session uses the circular log file mode. To specify no limit, specify a value of zero. The default value is 100 MB. When the log file size reaches its maximum size, the behavior depends on the value specified by the LogFileMode parameter.

Alias

none

Requis ?

false

Position ?

named

Valeur par défaut

none

Accepter l'entrée de pipeline ?

false

Accepter les caractères génériques ?

false

-MinimumBuffers<UInt32>

Specifies the minimum number of buffers to allocate at startup of the ETW session.

Alias

none

Requis ?

false

Position ?

named

Valeur par défaut

none

Accepter l'entrée de pipeline ?

false

Accepter les caractères génériques ?

false

-Name<String>

Specifies the name of the ETW trace session that this cmdlet creates.

Alias

none

Requis ?

true

Position ?

1

Valeur par défaut

none

Accepter l'entrée de pipeline ?

false

Accepter les caractères génériques ?

false

-ThrottleLimit<Int32>

Spécifie le nombre maximal d'opérations simultanées qui peuvent être établies pour exécuter l'applet de commande. Si ce paramètre est omis ou si la valeur 0 est entrée, Windows PowerShell® calcule un seuil de limitation optimal pour l'applet de commande en fonction du nombre d'applets de commande CIM exécutées sur l'ordinateur. Le seuil de limitation s'applique uniquement à l'applet de commande en cours, non pas à la session ou à l'ordinateur.

Alias

none

Requis ?

false

Position ?

named

Valeur par défaut

none

Accepter l'entrée de pipeline ?

false

Accepter les caractères génériques ?

false

-Confirm

Vous invite à confirmer l'exécution de l'applet de commande.

Requis ?

false

Position ?

named

Valeur par défaut

false

Accepter l'entrée de pipeline ?

false

Accepter les caractères génériques ?

false

-WhatIf

Indique ce qui se produit en cas d'exécution de l'applet de commande. L'applet de commande n'est pas exécutée.

Requis ?

false

Position ?

named

Valeur par défaut

false

Accepter l'entrée de pipeline ?

false

Accepter les caractères génériques ?

false

<CommonParameters>

Cette applet de commande prend en charge les paramètres courants : -Verbose, -Debug, -ErrorAction, -ErrorVariable, -OutBuffer et -OutVariable. Pour plus d'informations, consultez  . about_CommonParameters (https://go.microsoft.com/fwlink/p/?LinkID=113216).

<WorkflowParameters>

Entrées

Le type d'entrée correspond au type des objets que vous pouvez adresser à l'applet de commande.

Sorties

Le type de sortie correspond au type des objets que l'applet de commande émet.

Exemples

Example 1: Create an ETW trace session

This command creates an ETW trace session named NetCfgTrace that has a value of 24 for the MaximumBuffers parameter.

PS C:\> New-EtwTraceSession -Name "NetCfgTrace" -MaximumBuffers 24

Rubriques connexes

Get-EtwTraceSession

Remove-EtwTraceSession

Set-EtwTraceSession