Set-EtwTraceSession

適用対象: Windows 10, Windows Server Technical Preview

Set-EtwTraceSession

Modifies an ETW trace session.

構文

Parameter Set: ByName
Set-EtwTraceSession [-Name] <String[]> [-BufferSize <UInt32> ] [-CimSession <CimSession[]> ] [-ClockType <ClockType> {Performance | System | Cycle} ] [-FlushTimer <UInt32> ] [-LocalFilePath <String> ] [-LogFileMode <UInt32> ] [-MaximumBuffers <UInt32> ] [-MaximumFileSize <UInt32> ] [-PassThru] [-ThrottleLimit <Int32> ] [-Confirm] [-WhatIf] [ <CommonParameters>] [ <WorkflowParameters>]

Parameter Set: InputObject (cdxml)
Set-EtwTraceSession [-BufferSize <UInt32> ] [-CimSession <CimSession[]> ] [-ClockType <ClockType> {Performance | System | Cycle} ] [-FlushTimer <UInt32> ] [-LocalFilePath <String> ] [-LogFileMode <UInt32> ] [-MaximumBuffers <UInt32> ] [-MaximumFileSize <UInt32> ] [-PassThru] [-ThrottleLimit <Int32> ] [-Confirm] [-WhatIf] [ <CommonParameters>] [ <WorkflowParameters>]

詳細説明

The Set-EtwTraceSession cmdlet modifies an Event Trace for Windows (ETW) trace session. After you run this cmdlet, changes become effective immediately. You do not need to stop and restart the session.

パラメーター

-BufferSize<UInt32>

Specifies the size, in kilobytes, of buffers. We recommend less than 1000 kilobytes. If you do not specify a value for this parameter, ETW uses the size of physical memory to calculate a default value.

Aliases

none

必須/オプション

false

位置

named

既定値

none

パイプライン入力の受け入れ

false

ワイルドカード文字の受け入れ

false

-CimSession<CimSession[]>

リモート セッションまたはリモート コンピューターでコマンドレットを実行します。コンピューター名またはセッション オブジェクト (New-CimSession コマンドレットや Get-CimSession コマンドレットの出力など) を入力します。既定値は、ローカル コンピューター上の現在のセッションです。

Aliases

Session

必須/オプション

false

位置

named

既定値

none

パイプライン入力の受け入れ

false

ワイルドカード文字の受け入れ

false

-ClockType<ClockType>

Specifies the timer to use for the time stamp for events. Valid values are:

-- Performance. Performance counter value (high resolution)
-- System. System timer
-- Cycle. CPU cycle counter

The default value is Performance on computers that run Windows Vista and subsequent versions of the Windows operating system. The default value is System for previous versions of the Windows operating system.

Aliases

none

必須/オプション

false

位置

named

既定値

none

パイプライン入力の受け入れ

false

ワイルドカード文字の受け入れ

false

-FlushTimer<UInt32>

Specifies the interval, in seconds, at which to flush trace buffers. The minimum value is 1 second. This forced flush is in addition to the automatic flush that occurs when a buffer is full and when the trace session stops.

For a real-time logger, the default value of zero means that the flush time is 1 second. You can configure a real-time logger by specifying a value of EVENT_TRACE_REAL_TIME_MODE for the LogFileMode parameter.

The default value is zero. By default, buffers are flushed only when they are full.

Aliases

none

必須/オプション

false

位置

named

既定値

none

パイプライン入力の受け入れ

false

ワイルドカード文字の受け入れ

false

-LocalFilePath<String>

Specifies the full path for an ETW log file.

Aliases

none

必須/オプション

false

位置

named

既定値

none

パイプライン入力の受け入れ

false

ワイルドカード文字の受け入れ

false

-LogFileMode<UInt32>

Specifies one or more log modes. For valid values, see Logging Mode Constants.

Instead of writing to a log file, you can specify either EVENT_TRACE_BUFFERING_MODE or EVENT_TRACE_REAL_TIME_MODE. EVENT_TRACE_BUFFERING_MODE avoids the cost of flushing the contents of the session to disk when the file system becomes available.

Autologger sessions do not support the EVENT_TRACE_FILE_MODE_NEWFILE logging mode.

If you specify EVENT_TRACE_FILE_MODE_APPEND, specify a value for the BufferSize parameter that is the same in both the logger and the file being appended.

Specify more than one log mode, add the values of the modes. For instance, to include both EVENT_TRACE_FILE_MODE_CIRCULAR, which has a value of 0x00000002, and EVENT_TRACE_NO_PER_PROCESSOR_BUFFERING, which has a value of 0x10000000, add 0x10000000 and 0x00000002 to obtain 0x1000002.

Aliases

none

必須/オプション

false

位置

named

既定値

none

パイプライン入力の受け入れ

false

ワイルドカード文字の受け入れ

false

-MaximumBuffers<UInt32>

Specifies the maximum number of buffers to allocate to the Autologger session. We recommend a value of the MinimumBuffers parameter plus twenty. The value must be greater than or equal to MinimumBuffers. If you do not specify a value for the current parameter, ETW uses the buffer size and the size of physical memory to calculate a default value.

This cmdlet can only increase the maximum number of buffers. It cannot decrease that number.

Aliases

none

必須/オプション

false

位置

named

既定値

none

パイプライン入力の受け入れ

false

ワイルドカード文字の受け入れ

false

-MaximumFileSize<UInt32>

Specifies the maximum size, in megabytes, of a log file. The session is closed when the maximum size is reached, unless the session uses the circular log file mode. To specify no limit, specify a value of zero. The default value is 100 MB. When the log file size reaches its maximum size, the behavior depends on the value specified by the LogFileMode parameter.

Aliases

none

必須/オプション

false

位置

named

既定値

none

パイプライン入力の受け入れ

false

ワイルドカード文字の受け入れ

false

-Name<String[]>

Specifies an array of names of the ETW trace sessions to modify.

Aliases

none

必須/オプション

true

位置

1

既定値

none

パイプライン入力の受け入れ

true(ByPropertyName)

ワイルドカード文字の受け入れ

false

-PassThru

Indicates that this cmdlet returns an object that represents the item on which it operates. By default, this cmdlet does not generate any output.

Aliases

none

必須/オプション

false

位置

named

既定値

none

パイプライン入力の受け入れ

false

ワイルドカード文字の受け入れ

false

-ThrottleLimit<Int32>

Specifies the maximum number of concurrent operations that can be established to run the cmdlet. If this parameter is omitted or a value of zero is entered, then Windows PowerShell® calculates an optimum throttle limit for the cmdlet based on the number of CIM cmdlets that are running on the computer. The throttle limit applies only to the current cmdlet, not to the session or to the computer.

Aliases

none

必須/オプション

false

位置

named

既定値

none

パイプライン入力の受け入れ

false

ワイルドカード文字の受け入れ

false

-Confirm

コマンドレットを実行する前に確認メッセージを表示します。

必須/オプション

false

位置

named

既定値

false

パイプライン入力の受け入れ

false

ワイルドカード文字の受け入れ

false

-WhatIf

コマンドレットが実行された場合に何が起きるのかを示します。コマンドレットは実行されません。

必須/オプション

false

位置

named

既定値

false

パイプライン入力の受け入れ

false

ワイルドカード文字の受け入れ

false

<CommonParameters>

このコマンドレットは共通のパラメーターをサポートしています(-Verbose、-Debug、-ErrorAction、-ErrorVariable、-OutBuffer、および -OutVariable)。詳細については、TechNet の「 「about_CommonParameters」 (https://go.microsoft.com/fwlink/p/?LinkID=113216) を参照してください。

<WorkflowParameters>

入力

入力型は、コマンドレットにパイプできるオブジェクトの型です。

出力

出力型は、コマンドレットが出力するオブジェクトの型です。

使用例

Example 1: Modifyies a trace sessiony

This command increases the maximum number of buffers for the trace session named NetCfgTrace.

PS C:\> Set-EtwTraceSession -Name "NetCfgTrace" -MaximumBuffers 24

関連項目

Logging Mode Constants

Get-EtwTraceSession

Remove-EtwTraceSession

Send-EtwTraceSession