New-AutologgerConfig

적용 대상: Windows 10, Windows Server Technical Preview

New-AutologgerConfig

Creates an Autologger configuration.

구문

Parameter Set: cim:CreateInstance0
New-AutologgerConfig -Name <String> [-BufferSize <UInt32> ] [-CimSession <CimSession[]> ] [-ClockType <ClockType> {Performance | System | Cycle} ] [-DisableRealtimePersistence <UInt32> ] [-FileCount <UInt32> ] [-FileMax <UInt32> ] [-FlushTimer <UInt32> ] [-Guid <String> ] [-LocalFilePath <String> ] [-LogFileMode <UInt32> ] [-MaximumBuffers <UInt32> ] [-MaximumFileSize <UInt32> ] [-MinimumBuffers <UInt32> ] [-Start <Enabled> {Disabled | Enabled} ] [-ThrottleLimit <Int32> ] [-Confirm] [-WhatIf] [ <CommonParameters>] [ <WorkflowParameters>]

자세한 설명

The New-AutologgerConfig cmdlet creates an Autologger configuration. An AutoLogger event tracing session records events that occur early in the operating system boot process, in addition to any other events. Applications and device drivers capture traces both before and after the user logs in. Restart the computer for the new configuration to initiate an Event Trace for Windows (ETW) trace session. Modify the ETW trace session by using the Set-EtwTraceSession and Remove-EtwTraceSession cmdlets.

매개 변수

-BufferSize<UInt32>

Specifies the size, in kilobytes, of buffers. We recommend less than 1000 kilobytes. If you do not specify a value for this parameter, ETW uses the size of physical memory to calculate a default value.

별칭

none

필수 여부

false

위치

named

기본값

none

파이프라인 입력 허용 여부

false

와일드카드 문자 허용 여부

false

-CimSession<CimSession[]>

원격 세션이나 원격 컴퓨터에서 cmdlet을 실행합니다. 컴퓨터 이름이나 New-CimSession 또는 Get-CimSession cmdlet의 출력과 같은 세션 개체를 입력하세요. 기본값은 로컬 컴퓨터 상의 현재 세션입니다.

별칭

Session

필수 여부

false

위치

named

기본값

none

파이프라인 입력 허용 여부

false

와일드카드 문자 허용 여부

false

-ClockType<ClockType>

Specifies the timer to use for the time stamp for events. Valid values are:

-- Performance. Performance counter value (high resolution)
-- System. System timer
-- Cycle. CPU cycle counter

The default value is Performance on computers that run Windows Vista and subsequent versions of the Windows operating system. The default value is System for previous versions of the Windows operating system.

별칭

none

필수 여부

false

위치

named

기본값

none

파이프라인 입력 허용 여부

false

와일드카드 문자 허용 여부

false

-DisableRealtimePersistence<UInt32>

Specifies whether to not persist real-time events that were not delivered before the time the computer was shutdown. Persisted events are delivered to the consumer the next time the consumer connects to the session. To disable real time persistence, specify a value of one. To persist events, specify a value of zero. The default is zero.

별칭

none

필수 여부

false

위치

named

기본값

none

파이프라인 입력 허용 여부

false

와일드카드 문자 허용 여부

false

-FileCount<UInt32>

Specifies the file count value.

별칭

none

필수 여부

false

위치

named

기본값

none

파이프라인 입력 허용 여부

false

와일드카드 문자 허용 여부

false

-FileMax<UInt32>

Specifies the maximum number of instances of the log file that ETW creates. Valid values are integers up to 16.

If the log file you specified with the LocalFilePath parameter exists, ETW appends the FileCounter value to the file name. For example, if the default log file name is used, the form is %SystemRoot%\System32\LogFiles\WMI\<sessionname>.etl.NNNN.

The first time you start the computer, the file name is <sessionname>.etl.0001. The second time, the file name is <sessionname>.etl.0002. If you specify a value of 3 for FileMax, then at the fourth start of the computer, ETW resets the counter to one (1), and then overwrites <sessionname>.etl.0001.

별칭

none

필수 여부

false

위치

named

기본값

none

파이프라인 입력 허용 여부

false

와일드카드 문자 허용 여부

false

-FlushTimer<UInt32>

Specifies the interval, in seconds, at which to flush trace buffers. The minimum value is one second. This forced flush is in addition to the automatic flush that occurs when a buffer is full and when the trace session stops.

For a real-time logger, the default value of zero means that the flush time is one second. You can configure a real-time logger by specifying a value of EVENT_TRACE_REAL_TIME_MODE for the LogFileMode parameter.

The default value is zero. By default, buffers are flushed only when they are full.

별칭

none

필수 여부

false

위치

named

기본값

none

파이프라인 입력 허용 여부

false

와일드카드 문자 허용 여부

false

-Guid<String>

Specifies a GUID, as a string, that uniquely identifies the session.

별칭

none

필수 여부

false

위치

named

기본값

none

파이프라인 입력 허용 여부

false

와일드카드 문자 허용 여부

false

-LocalFilePath<String>

Specifies the full path for an ETW log file.

별칭

none

필수 여부

false

위치

named

기본값

none

파이프라인 입력 허용 여부

false

와일드카드 문자 허용 여부

false

-LogFileMode<UInt32>

Specifies one or more log modes. For valid values, see Logging Mode Constants.

Instead of writing to a log file, you can specify either EVENT_TRACE_BUFFERING_MODE or EVENT_TRACE_REAL_TIME_MODE. EVENT_TRACE_BUFFERING_MODE avoids the cost of flushing the contents of the session to disk when the file system becomes available.

Autologger sessions do not support the EVENT_TRACE_FILE_MODE_NEWFILE logging mode.

If you specify EVENT_TRACE_FILE_MODE_APPEND, specify a value for the BufferSize parameter that is the same in both the logger and the file being appended.

Specify more than one log mode, add the values of the modes. For instance, to include both EVENT_TRACE_FILE_MODE_CIRCULAR, which has a value of 0x00000002, and EVENT_TRACE_NO_PER_PROCESSOR_BUFFERING, which has a value of 0x10000000, add 0x10000000 and 0x00000002 to obtain 0x1000002.

별칭

none

필수 여부

false

위치

named

기본값

none

파이프라인 입력 허용 여부

false

와일드카드 문자 허용 여부

false

-MaximumBuffers<UInt32>

Specifies the maximum number of buffers to allocate to the Autologger session. We recommend a value of the MinimumBuffers parameter plus twenty. The value must be greater than or equal to MinimumBuffers. If you do not specify a value for the current parameter, ETW uses the buffer size and the size of physical memory to calculate a default value.

별칭

none

필수 여부

false

위치

named

기본값

none

파이프라인 입력 허용 여부

false

와일드카드 문자 허용 여부

false

-MaximumFileSize<UInt32>

Specifies the maximum size, in megabytes, of a log file. The session is closed when the maximum size is reached, unless the session uses the circular log file mode. To specify no limit, specify a value of zero. The default value is 100 MB. When the log file size reaches its maximum size, the behavior depends on the value specified by the LogFileMode parameter.

별칭

none

필수 여부

false

위치

named

기본값

none

파이프라인 입력 허용 여부

false

와일드카드 문자 허용 여부

false

-MinimumBuffers<UInt32>

Specifies the minimum number of buffers to allocate at startup of the Autologger session. The minimum number of buffers that you can specify is two buffers per processor.

별칭

none

필수 여부

false

위치

named

기본값

none

파이프라인 입력 허용 여부

false

와일드카드 문자 허용 여부

false

-Name<String>

Specifies the name of the Autologger configuration.

별칭

none

필수 여부

true

위치

named

기본값

none

파이프라인 입력 허용 여부

true(ByValue)

와일드카드 문자 허용 여부

false

-Start<Enabled>

Specifies whether to activate the Autologger session at the next computer restart. Valid values are: Disabled and Enabled.

별칭

none

필수 여부

false

위치

named

기본값

none

파이프라인 입력 허용 여부

false

와일드카드 문자 허용 여부

false

-ThrottleLimit<Int32>

Specifies the maximum number of concurrent operations that can be established to run the cmdlet. If this parameter is omitted or a value of zero is entered, then Windows PowerShell® calculates an optimum throttle limit for the cmdlet based on the number of CIM cmdlets that are running on the computer. The throttle limit applies only to the current cmdlet, not to the session or to the computer.

별칭

none

필수 여부

false

위치

named

기본값

none

파이프라인 입력 허용 여부

false

와일드카드 문자 허용 여부

false

-Confirm

cmdlet을 실행하기 전에 확인 메시지를 표시합니다.

필수 여부

false

위치

named

기본값

false

파이프라인 입력 허용 여부

false

와일드카드 문자 허용 여부

false

-WhatIf

cmdlet이 실행되는 경우 발생할 결과를 보여 줍니다. cmdlet은 실행되지 않습니다.

필수 여부

false

위치

named

기본값

false

파이프라인 입력 허용 여부

false

와일드카드 문자 허용 여부

false

<CommonParameters>

이 cmdlet은 -Verbose, -Debug, -ErrorAction, -ErrorVariable, -OutBuffer, -OutVariable 등의 일반 매개 변수를 지원합니다. 자세한 내용은 TechNet의 about_CommonParameters(https://go.microsoft.com/fwlink/p/?LinkID=113216)

<WorkflowParameters>

입력

입력 형식은 cmdlet으로 파이프할 수 있는 개체의 형식입니다.

출력

출력 형식은 cmdlet 실행 시 출력되는 개체의 형식입니다.

Example 1: Create a configuration

This command creates an Autologger configuration named WFP-IPsec Trace.

PS C:\> New-AutoLoggerconfig -Name "WFP-IPsec Trace"

관련 항목

Configuring and Starting an AutoLogger Session

Logging Mode Constants

WNODE_HEADER structure

Get-AutologgerConfig

Remove-AutologgerConfig

Set-AutologgerConfig

Remove-EtwTraceSession

Set-EtwTraceSession