Remove-SCStorageFabricClassification
Remove-SCStorageFabricClassification
Removes a Fibre Channel fabric classification from VMM.
Syntax
Parameter Set: Default
Remove-SCStorageFabricClassification [-StorageFabricClassification] <StorageFabricClassification> [-JobVariable <String> ] [-PROTipID <Guid]> ] [-RunAsynchronously] [-Confirm] [-WhatIf] [ <CommonParameters>]
Detailed Description
The Remove-SCStorageFabricClassification cmdlet removes a Fibre Channel fabric classification from Virtual Machine Manager (VMM).
Parameters
-JobVariable<String>
Specifies that job progress is tracked and stored in the variable named by this parameter.
Aliases |
none |
Required? |
false |
Position? |
named |
Default Value |
none |
Accept Pipeline Input? |
false |
Accept Wildcard Characters? |
false |
-PROTipID<Guid]>
Specifies the ID of the PRO tip that triggered this action. This allows for auditing of PRO tips.
Aliases |
none |
Required? |
false |
Position? |
named |
Default Value |
none |
Accept Pipeline Input? |
false |
Accept Wildcard Characters? |
false |
-RunAsynchronously
Indicates that the job runs asynchronously so that control returns to the command shell immediately.
Aliases |
none |
Required? |
false |
Position? |
named |
Default Value |
none |
Accept Pipeline Input? |
false |
Accept Wildcard Characters? |
false |
-StorageFabricClassification<StorageFabricClassification>
Specifies a classification for storage Fibre Channel fabric.
Aliases |
none |
Required? |
true |
Position? |
1 |
Default Value |
none |
Accept Pipeline Input? |
True (ByValue) |
Accept Wildcard Characters? |
false |
-Confirm
Prompts you for confirmation before running the cmdlet.
Required? |
false |
Position? |
named |
Default Value |
false |
Accept Pipeline Input? |
false |
Accept Wildcard Characters? |
false |
-WhatIf
Shows what would happen if the cmdlet runs. The cmdlet is not run.
Required? |
false |
Position? |
named |
Default Value |
false |
Accept Pipeline Input? |
false |
Accept Wildcard Characters? |
false |
<CommonParameters>
This cmdlet supports the common parameters: -Verbose, -Debug, -ErrorAction, -ErrorVariable, -OutBuffer, and -OutVariable. For more information, see about_CommonParameters (https://go.microsoft.com/fwlink/p/?LinkID=113216).
Inputs
The input type is the type of the objects that you can pipe to the cmdlet.
Outputs
The output type is the type of the objects that the cmdlet emits.
- StorageFabricClassification
Examples
Example 1: Remove a storage fabric classification
This command gets the storage fabric classification object named PROD, and uses the pipeline operator to pass the object to Remove-SCStorageFabricClassification. That cmdlet removes the classification from VMM.
PS C:\> Get-SCStorageFabricClassification -Name "PROD" | Remove-SCStorageFabricClassification
Related topics
Get-SCStorageFabricClassification