New-NetEventSession

New-NetEventSession

Creates a network event session.

Syntaxe

Parameter Set: cim:CreateInstance0
New-NetEventSession [-Name] <String> [-CaptureMode <CaptureModes> {RealtimeRPC | SaveToFile | RealtimeLocal} ] [-CimSession <CimSession[]> ] [-LocalFilePath <String> ] [-MaxFileSize <UInt32> ] [-MaxNumberOfBuffers <Byte> ] [-ThrottleLimit <Int32> ] [-TraceBufferSize <UInt32> ] [-Confirm] [-WhatIf] [ <CommonParameters>] [ <WorkflowParameters>]

Description détaillée

The New-NetEventSession cmdlet creates a network event session. A session controls how the computer logs events and, optionally, network traffic, or packets. Add network event providers to a session. A network event provider logs events and network traffic as Event Tracing for Windows (ETW) events. The session stores these events in an .etl file or provides them to an application that displays them.

Assign a name for the session. Only one session can exist at a time. Remove an existing session by using the Remove-NetEventSession cmdlet. You can specify the maximum number of buffers in a session and the size of the trace buffer.

You can also specify whether to use an.etl file and, if you do, specify its location and maximum size. Instead of an .etl file, you can select a type of live display.

After you create a session, you can use the Set-NetEventSession cmdlet to modify the session settings. After you create a session, add one or more providers to it by using the Add-NetEventProvider cmdlet. Use the Start-NetEventSession and Stop-NetEventSession cmdlets to start and stop logging.

Paramètres

-CaptureMode<CaptureModes>

Specifies a capture mode. Les valeurs acceptables pour ce paramètre sont :

-- SaveToFile. Saves the capture to an .etl file.
-- RealtimeRPC. Connects remotely for a live event and packet capture.
-- RealtimeLocal. Connects locally for a live event and packet capture.

If you specify a value of SaveToFile, you can specify a location for the file by using the LocalFilePath parameter and specify a maximum file size by using the MaxFileSize parameter.

If you specify a value of RealtimeRPC or RealtimeLocal, the capture requires additional software, such as Microsoft Message Analyzer..

Alias

cm

Obligatoire ?

false

Position ?

named

Valeur par défaut

none

Accepter l’entrée de pipeline ?

false

Accepter les caractères génériques ?

false

-CimSession<CimSession[]>

Exécute l’applet de commande dans une session à distance ou sur un ordinateur distant. Entrez un nom d’ordinateur ou un objet de session, comme la sortie d’une applet de commande New-CimSession ou Get-CimSession. La valeur par défaut est la session active sur l’ordinateur local.

Alias

Session

Obligatoire ?

false

Position ?

named

Valeur par défaut

none

Accepter l’entrée de pipeline ?

false

Accepter les caractères génériques ?

false

-LocalFilePath<String>

Specifies a file path. If you specify a value of SaveToFile for the CaptureMode parameter, the cmdlet saves the file to this location. Be sure that you can write to this location. If you do not specify this parameter, the cmdlet uses the default value of %LocalAppData%\Temp\NetTrace.etl.

Alias

lfp

Obligatoire ?

false

Position ?

named

Valeur par défaut

none

Accepter l’entrée de pipeline ?

false

Accepter les caractères génériques ?

false

-MaxFileSize<UInt32>

Specifies a maximum file size, in megabytes. If you specify a value of SaveToFile for the CaptureMode parameter, this value is the maximum size for the .etl file. Once the file reaches the maximum, the session continues to save events, and discards the oldest events to make room. A value of 0 means that there is no maximum. If you do not specify this parameter, the cmdlet uses a default value of 250.

Alias

none

Obligatoire ?

false

Position ?

named

Valeur par défaut

none

Accepter l’entrée de pipeline ?

false

Accepter les caractères génériques ?

false

-MaxNumberOfBuffers<Byte>

Specifies the maximum number of buffers used in a session. If the computer determines that the value restricts performance or the value is 0, the computer overrides the configuration to optimize trace performance. For more information, see EVENT_TRACE_PROPERTIES structure (https://msdn.microsoft.com/en-us/library/windows/desktop/aa363784(v=vs.85).aspx) In the Microsoft Developer Network library.

Alias

none

Obligatoire ?

false

Position ?

named

Valeur par défaut

none

Accepter l’entrée de pipeline ?

false

Accepter les caractères génériques ?

false

-Name<String>

Specifies a name to assign to the session for event and packet capture.

Alias

none

Obligatoire ?

true

Position ?

1

Valeur par défaut

none

Accepter l’entrée de pipeline ?

false

Accepter les caractères génériques ?

false

-ThrottleLimit<Int32>

Spécifie le nombre maximal d’opérations simultanées qui peuvent être établies pour exécuter cette applet de commande. Si ce paramètre est omis ou si la valeur 0 est entrée, Windows PowerShell ® calcule une limitation optimale pour l’applet de commande en fonction du nombre d’applets de commande CIM qui s’exécutent sur l’ordinateur. La limitation s’applique seulement à l’applet de commande actuelle, et non pas à la session ni à l’ordinateur.

Alias

none

Obligatoire ?

false

Position ?

named

Valeur par défaut

none

Accepter l’entrée de pipeline ?

false

Accepter les caractères génériques ?

false

-TraceBufferSize<UInt32>

Specifies the amount of memory, in kilobytes, for a buffer for event tracing. The maximum value is 1024. If the computer determines that the value restricts performance or the value is 0, the computer overrides the configuration to optimize trace performance. The ETW logger uses the size of physical memory to calculate the default value.

Alias

none

Obligatoire ?

false

Position ?

named

Valeur par défaut

none

Accepter l’entrée de pipeline ?

false

Accepter les caractères génériques ?

false

-Confirm

Votre confirmation sera requise avant l’exécution de l’applet de commande.

Obligatoire ?

false

Position ?

named

Valeur par défaut

false

Accepter l’entrée de pipeline ?

false

Accepter les caractères génériques ?

false

-WhatIf

Présente les conséquences éventuelles de l’exécution de l’applet de commande. L’applet de commande n’est pas exécutée.

Obligatoire ?

false

Position ?

named

Valeur par défaut

false

Accepter l’entrée de pipeline ?

false

Accepter les caractères génériques ?

false

<CommonParameters>

Cette applet de commande prend en charge les paramètres courants : -Verbose, -Debug, -ErrorAction, -ErrorVariable, -OutBuffer et -OutVariable. Pour plus d’informations, consultez about_CommonParameters (https://go.microsoft.com/fwlink/p/?LinkID=113216).

<WorkflowParameters>

Cette applet de commande prend en charge les paramètres de workflow courants suivants : -PSParameterCollection, -PSComputerName, -PSCredential, -PSConnectionRetryCount, -PSConnectionRetryIntervalSec, -PSRunningTimeoutSec, -PSElapsedTimeoutSec, -PSPersist, -PSAuthentication, -PSAuthenticationLevel, -PSApplicationName, -PSPort, -PSUseSSL, -PSConfigurationName, -PSConnectionURI, -PSAllowRedirection, -PSSessionOption, -PSCertificateThumbprint, -PSPrivateMetadata, -AsJob, -JobName et –InputObject. Pour plus d’informations, consultez  about_WorkflowCommonParameters.

Entrées

Le type d’entrée correspond au type des objets que vous pouvez transmettre à l’applet de commande.

Sorties

Le type de sortie est le type des objets émis par l’applet de commande.

Exemples

Example 1: Create a session

This command creates session named Session38. Use the Add-NetEventProvider cmdlet to add a provider for the session.

PS C:\> New-NetEventSession -Name "Session38"

Rubriques connexes

Get-NetEventSession

Remove-NetEventSession

Set-NetEventSession

Start-NetEventSession

Stop-NetEventSession

Add-NetEventProvider